What's new on Artica 4.50 LTS
Here the changes between the 4.30x LTS and the 4.50
The 4.50 includes all changes from the 4.40 nightly build
203 Changes since the v4.30 LTS
- SP10: Fix: Loop errors Error, cache-tail daemon not running.. when the proxy is not installed
- SP10: Fix: Avoid kerberos Request is a replay issue ( see https://wiki.articatech.com/en/proxy-service/troubleshooting/gss-request-is-a-replay )
- SP10: Fix: Artica tries to run the go-shield service in an SMTP gateway environment only..
- SP10: function that removes installed service packs for older Artica versions.
- SP10: Add possibility to create Macvlan interfaces ( see https://wiki.articatech.com/en/network/macvlan )
- SP10: Change: Virtual Network interfaces label is changed to IP aliasing ( see https://wiki.articatech.com/en/network/ip-aliases )
- SP10: Add WFI4EU support in the HotSpot see ( https://wiki.articatech.com/en/proxy-service/hotspot/wifi4eu-compliance )
- SP10: Add: New feature multiple SMTP gateways on the same server ( see https://wiki.articatech.com/en/smtp-service/multi )
- SP11: Fix: False alarm on bad cloning device on VMWare system.
- SP11: Add: Possibility to send SMTP instances events to a remote syslog system ( https://wiki.articatech.com/en/smtp-service/multi/syslog )
- SP12: Fix: Issues when creating new SMTP instance.
- SP12: Add: New SMTP Tool to test an SMTP server by sending an email.( see https://wiki.articatech.com/web-console/Tools/smtp-simulation )
- SP13: Add: Watchdog that fix a file descriptors issue after rebooting the server ( see https://wiki.articatech.com/en/proxy-service/troubleshooting/filedescriptors-reboot )
- SP13: Fix: If Filtering service configuration is not saved first (go-shield-server), service cannot start.
- SP14: Add: New Active Directory Proxy authentication method using only LDAP ( see https://wiki.articatech.com/en/proxy-service/authentication/ldap )
- SP14: Add: Start Radus Service support beta 1 ( see https://wiki.articatech.com/system/radius )
- SP14: Add: Possibility to reset RRD databases ( see https://wiki.articatech.com/web-console/reset-rrd )
- SP15: Fix: Removing the Filtering service did not disconnect the go-shield-client to the proxy.
- SP15: Add: Statistics of active connections and requests for the reverse-proxy service.
- SP15: Add: widget on the dashboard when using only the reverse proxy service.
- SP15: Add: Possibility to change the listen interface of the proxy-pac service.
- SP15: Ensure that 127.0.0.5* is not used except for the DNS Cache service.
- SP16: Add: new statistics for wordpress websites ( see https://wiki.articatech.com/wordpress/connections-statistics )
- SP16: Fix: Wrong order in Proxy SSL rules that make decrypt unstable when decrypt/encrypt rules with same objects.
- SP16: Fix: Unable to add a new ACL object when using object list section.
- SP16: Add: When creating a new IP source or desintation object and an IP is on the object subject, an item is automatically added with such subject.
- SP16: Fix: Uninstall reverse-proxy feature did not uninstall Web firewall feature
- SP16: Fix: Remove warning of no websites defined in HotSpot
- SP16: Fix: Artica killing local DNS Cache service when DNS Cache is enabled.
- SP16: Add: Automatic response on proxy issue "negotiate_kerberos_auth: FATAL: Local hostname could not be determined. Please specify the service principal"
- SP16: Fix: In HotSpot Web (v4.40.40) unable to logon using voucher ticket
- SP16: Fix: Go shield 1.0.63 add error handling for invalid urls
- SP16: Fix: Typo in exec.go.shield.server.php
- SP17: Fix: MySQL database is not checked when upgrading PowerDNS version.
- SP17: Fix: freeradius-utils package need to be installed as Radius feature is not enabled.
- SP17: Fix: ElasticSearch API for pyhton warning as the ElasticSearch feature is not installed.
- SP17: Fix: Unable to change DNS settings using the Unix console.
- SP17: Fix: smtps protocol was not understood in Artica SMTP notification daemon.
- SP17: Add: Possibility to specify an outgoing interface in Artica SMTP notification daemon.
- SP17: Add: Possibility to turn into debug mode the Artica SMTP notification daemon
- SP17: Add: Automatically updating the Artica SMTP notification daemon with updates.
- SP17: Add: Possibility to upgrade Filtering service using packages manager.
- SP18: Add: Yoast support plugin for Artica for Wordpress edition ( see https://wiki.articatech.com/en/wordpress/yoast )
- SP18: Fix: Parent proxy load-balancer engine was not removed if proxy or feature is removed
- SP18: Fix: Allowed network of SMTP notifications service is only limited to 127.0.0.1
- SP18: Update: 1.37.0 Advanced Monitoring service version on repository
- SP18: Fix: Sometimes the Active Directory emergency is still Active. Add a new function to detect it and warn about the emergency activation.
- SP18: Fix: Unable to change SuperAdmin using Unix console
- SP18: Fix: issue while enabling the reverse-proxy cache.
- SP19: Fix: Conflict with proxy-pac service and systemd
- SP19: Fix: Update proxy-pac service to 1.2.10
- SP19: Fix: Unable to simulate Proxy.pac rules
- SP19: Add: More buttons for compiling/simulate in proxy.pac sections
- SP20: Add: Possibility to install PostgreSQL using packages center.
- SP21: Add: More verifications and processing when upgrading PostgreSQL database
- SP22: Fix: Remove proftpd-mod-sqlite warning if ProFTPD is not enabled
- SP22: Fix: Remove warning for python module for DNS Cache.
- SP22: Fix: Remove warning on missing Perl mail-to-HTML converter if messaging is not enabled.
- SP22: Add: Possibility to remove the OpenLDAP service inside the OpenLDAP section.
- SP22: Fix: Unable to display Redis server events.
- SP22: Add: Possibility to send Redis server events to a remote syslog server.
- SP22: Add: Remove The web interface framework using lighttpd web service. Now communicating directly to the PHP-FPM service.
- SP23: Fix: Framework was not restarted after Service Pack 22 ( need reboot server to fix it )
- SP24: Add: Support of upgrading Redis server software ( see https://wiki.articatech.com/system/redis/update-bell )
- SP24: Fix: Internet access section need to set proxy password as the use of proxy is disabled.
- SP24: Fix: Unable to active or install wordpress website ( see https://wiki.articatech.com/wordpress/install )
- SP24: Add: Support of notify upgrading wordpress system client new version.
- SP24: Add: New watchdog function for framework unix socket checking.
- SP24: Add: Support of CVE-2021-44142 ( see https://wiki.articatech.com/maintenance/security/CVE-2021-44142 )
- SP24: Add: Support of CVE-2022-29155 ( see https://wiki.articatech.com/maintenance/security/CVE-2022-29155 )
- SP24: Add: Possibility to restore an Artica backuped wordress ( see https://wiki.articatech.com/wordpress/restore-backup )
- SP24: Add: Possibility to replace value in the wordpress database ( see https://wiki.articatech.com/wordpress/replace-in-database )
- SP24: Fix: Bypass Active Directory authentication is not correctly formatted when saving destination domains ( see http://bugs.articatech.com/show_bug.cgi?id=345 ).
- SP24: Add: New feature to bypass Google Earth ( see http://bugs.articatech.com/show_bug.cgi?id=248 )
- SP24: Add: Artica snapshots tasks write events to syslog
- SP25: Add: New watchdog in case of framework issue - the Web console warn about the communication issue.
- SP25: Add: Possibility to turn on debug a reverse-proxy website ( see https://wiki.articatech.com/reverse-proxy/debugging )
- SP25: Add: Possibility to define a Response Policy zone in PowerDNS ( https://wiki.articatech.com/en/dns/PowerDNS/rpz )
- SP26: Fix: Framework migration bug ( see http://bugs.articatech.com/show_bug.cgi?id=347 )
- SP26: Fix: SQL Error on the PowerDNS RPZ Section.
- SP26: Fix: Reverse-proxy Conflits between Web application Firewall and Redis Caching.
- SP26: Fix: Unable to install Redis service using new framework.
- SP26: Fix: SQL Error: no such table: wp_sites
- SP27: Fix: Web Firewall tables are not created after enabling the feature.
- SP27: Fix: SSL Client certificate issue in reverse-proxy when there is space in Certificate name.
- SP27: Fix: Caching images provides 404 not found on the reverse proxy service.
- SP27: Add: Optimizing Website will now use Redis service if enabled.
- SP27: Add: HIT/MISS in reverse-proxy access logs.
- SP28: Add: Fix Encryption types issues with Active Directory on HaCluster after Microsoft Windows 2019 November 2022 updates
- SP28: Add: Proxy Protocol v2 support on SMTP service ( see https://wiki.articatech.com/en/smtp-service/load-balancer-compliance )
- SP28: Fix: /var/log/kibana/kibana.stdout and /var/log/kibana/kibana.stderr log files are not monitored for cleaning.
- SP28: Fix: Uploading a new Service Pack in Web console make the progress stuck at 5% but update process is correctly performed.
- SP28: Add: "Online Help" Button in IPSEC, Failover, Splunk and Network
- SP28: Fix: Typo in exec.clean.logs.php
- SP28: Add: Missing ha-diagram-animated.gif img
- SP28: Add: Dropdown button for "New Interface" when bounding is enable
- SP28: Fix: Issues on Characters set when upgrading to the lastest PowerDNS version ( see https://wiki.articatech.com/en/dns/PowerDNS/Errors/GSQLBackend-domain )
- SP28: Fix: Reverse-proxy log all checks/accesses from the local monitor
- SP28: Fix: Progress bar in IDS section
- SP28: Add: Log rotate support for go-shield logs
- SP28: Add: Improvements of WebCopy feature ( see https://wiki.articatech.com/en/reverse-proxy/WebCopy )
- SP29: Fix: WebCopy tab is displayed on Reverse-proxy web server settings
- SP29: Add: Rebuild the proxy blacklist list section.
- SP29: Fix: Issues with Web-Filtering engine and Personal categories
- SP30: Add: New notifications for Web-filter engine and Web-Filter new versions.
- SP30: Add: Speedup the Artica Web console by forcing browsers to cache images, css, woff, woff2 files.
- SP30: Fix: Typo in Artica virtual_aliases_map in Artica SMTP edition.
- SP31: Fix: missconfigurations in remote syslog rules with "all" token that make the syslog service unavailable.
- SP31: Fix: Minors bugs on Active Directory LDAP group searchs.
- SP32: Fix: Issue on progress bar when uploading a new service Pack in update section
- SP33: Fix: Progress bar change to red where there is no changes in rsyslog configuration.
- SP33: Fix: issue on TCP syslog port.
- SP33: Add: Possibility to change the hostname in remote syslog configuration ( see https://wiki.articatech.com/system/syslog/sent-hostname )
- SP33: Add: Introduce a Log Sink feature ( not finish )
- SP33: Fix: rsyslog issue when create a remote syslog rule with all events.
- SP33: Fix: Incompatibility beetween php 7.0 (Debian 9 ) and php 8.2 in Artica For Wordpress framework.
- SP33: Add: Number of events sent by the syslog engine in remote syslog events feature
- SP34: Add: OpenDNS and OpenDNS family support.
- SP34: Update: Proxy LDAP groups search plugin to 1.0.16
- SP35: Fix: Unable to reboot the server using the web console
- SP35: Fix: Associated images and js files are not implemented in templates in web error page service.
- SP35: Add: Hotspot accept active directory users if no Active Directory group filter is defined.
- SP35: Add: Possibility to manage the Active Directory Kerberos renewal ( see https://wiki.articatech.com/active-directory/kerberos/renew )
- SP35: Add: Possiblity to download hostpot logs
- SP35: Add: Possibility to empty HotSpot logs.
- SP36: Fix: License section did not have all buttons if registration process is not done.
- SP36: Add: Updated new v4.40 ISO with service Pack 36
- SP37: Fix: Unable to insert pictures objects inside the Web-filtering error page template.
- SP37: fix "nopreempt" in failover
- SP37: Add better support detection for Proxy failores (Emergency modes, curl test to check connectivity)
- SP37: Add Support detection for DNS Firewall and DNS Cache
- SP38: Fix: PTY allocation request failed on channel 0 on OpenSSH service
- SP38: Change: Artica Backup task is removed from the schedule task and have its own section.
- SP39: Fix: Glances, Netdata broken since v4.40 release caused by js/css caching on the web console - need to restart webconsole
- SP40: Add: function that kill apache in memory that is executed by systemd after system upgrade. this cause the proxy-pac service down.
- SP40: Fix: Unable to install dwagent.
- SP40: Add: More options to tune the login page.
- SP40: Fix: XSS operations on the login page.
- SP40: Fix: DNS backends typo error when no port defined and false checks on resolve names in DNS Firewall service.
- SP40: Fix: Categories databases cache are not flushed where all personal categories are deleted.
- SP40: Add: Better button for empty the go-shield cache.
- SP40: Add: If Parent Proxy is enable, the Internet Access test is made against parent proxy instead proxy service in failover method.
- SP40: update: Go Squid Auth 1.0.18 that allow search Universal Groups under normal ldap ports 389 and 636
- SP42: Fix: Unable to start PostgreSQL daemon on fresh artica v4.40 installations.
- SP44: Fix: Unable to apply configuration on DNS Firewall.
- SP44: Fix: Acls issues on DNS Firewall in order to obtain informations for the DNS Firewal web service.
- SP44: Fix: Progress bar stuck when updating settings on The Shield section.
- SP44: Add: Navigation buttons on DNS firewall to navigate between DNS Firewall rules and service status.
- SP44: Remove: DNS Filtering it switched by DNS Firewall.
- SP44: Fix: Missing libmongoc-1.0-0 Debian package for NetData
- SP44: Fix: Cache not removed on personal categories changes.
- SP44: Fix: Active Directory search group api updated to support MemberOf attribute
- SP44: Fix: Conflicts between systemd that handle unbound ( DNS Cache service )
- SP46: Fix: Proxy Connector menu in Filtering is displayed as there is no Proxy service installed.
- SP46: Fix: Non-default parameter set in the Active Directory LDAP search group that cause the proxy to refuse connection after an ACL with Active Directory group.
- SP46: Add: New feature Boot Manager ( see https://wiki.articatech.com/en/system/system-console/boot )
- SP48: Add: Possibility to enable/disable TCP KeepAlive on proxy ports.
- SP48: Fix: Access rules in a reverse-proxy subfolder without reverse-proxy directive perform a 404 not found when allowed
- SP50: Add: Possibility to lock the selected language
- SP50: Add: Possibility to choose the language in wizard installation.
- SP52: Add: Possibility to update "keytab client for MS Active Directory"
- SP52: Fix: unstructured forms on title/explain sections
- SP52: Update: Virtual appliance for VMWare ESXI
- SP54: Fix: periodic SQLite error on no such table: vouchers
- SP54: Fix: periodic SQLite error on wpad_rules
- SP54: Fix: Wrong translate on the local DNS cache ip cache size.
- SP54: Add: Rebuild the interface for local DNS cache to more be easy to understand.
- SP54: Fix: FATAL: PostgreSQL Failed while calculating table size with could not open shared memory segment on PostgreSQL on server less than 4GB of memory
- SP54: Add: Possibility to play with kernel.shmmax and kernel.shmall
- SP54: Fix: Active Directory connections are not correcly saved in Hotspot configation.
- SP54: Add: 2 wizards for DNS Firewall in order to block ads and malwares easily.
- SP56: Add: Possibility to set user without "@" for Active directory authentication
- SP56: Fix: Adding yandex and duckduckgo SafeSearch disables all rules in DNS Firewall
- SP58: Add: Compatibility of Office365 for SMTP notifications ( see https://wiki.articatech.com/en/system/smtp-notifications/574-office365 )
- SP58: Fix: HotSpot background image is not displayed when uploading a new one.
- SP58: Add: XSS Protection on the login page with Cookies.
- SP58: Fix: SQL Injections in categories search
- SP60: Add: SafeSearch options on the local DNS Cache service.
- SP60: Add: Possibility to transform the local DNS cache on a network DNS cache.
- SP60: Add: More checks and tests on the Active Directory LDAP Basic authentication.
- SP60: Fix: Wrong object activation information on TheShields in DNS Firewall.
- SP60: Add: SafeSearchs are now a part of DNS Firewall rules that allows to Admin to specify sources addresses that will be redirected to SafeSearchs engines.
- SP62: Fix: Minors bugs on the Universal Proxy service.
- SP62: Add: New Feature SSH Proxy service ( see https://wiki.articatech.com/en/ssh/sshproxy )
- SP62: Fix: Upgrade to PHP4 cause the installation of PHP 8.x that is currently incompatible with Artica.
- SP62: Fix: PHP 8.x compatibility issues 30%
- SP64: Fix: Compatibilities issues with php 7.0 on Debian 9 on SP62
- SP66: Fix: Refresh index did not work on Artica update section
- SP66: Fix: Unable to change groups order in ACLs
- SP66: Fix: Wizard - all to xxx is added every time as there is an already rule defined in proxy-Pac Service
- SP66: Add: Possibility to Import/export Proxy Pac rules ( see https://wiki.articatech.com/en/proxy-service/proxy-pac/import-export )
- SP66: Add: Possibility to see all acls objects inside the Proxy Pac section.
- SP66: Add: Possibility to find any records inside Proxy PAC rules. ( see https://wiki.articatech.com/proxy-service/proxy-pac/search )
- SP66: Add: Possibility to download the generated proxy.pac file for each rule.
- SP66: Fix: Issue on chmod on the Samba path when the NTLM watchdog check the Active Directory availability.
- SP66: Fix: PHP Fatal error: Uncaught Error: Class hollodotme\FastCGI\Exceptions\TimedoutException on Artica Framework.
- SP66: Add: Improve the DNS Firewall service monitor availability.
- SP68: Fix: urls records are not understood in proxy.pac builder
- SP68: Fix: XSS attacks on Cookies sessions.
- SP68: Add: Possibility to upgrade the Artica Web console in order to enable HTTP/2
- SP68: Fix: Errors in proxy.pac generation
- SP70: Add: improve navigation inside ACLs forms and tables.
- SP70: Fix: Sometimes when apply the configuration, the proxy service is not reloaded.
- SP70: Add: Proxy PAC service to v1.2.11 with better performance on HTTP engine.
- SP70: Add: New feature "Log sink" ( see https://wiki.articatech.com/system/syslog/log-sink )
- SP72: Fix: Sometimes ,the watchdog was not correctly synchronized with the DNS Cache service.
- SP72: Add: New watchdog for the local DNS cache service ( see https://wiki.articatech.com/dns/local-dns-service/watchdog )
- SP72: Fix: When compiling rules on the Auto-mount feature, the progress stuck at 5%
- SP74: Add: Possibility to repair a MySQL database of a Wordpress website ( see https://wiki.articatech.com/en/wordpress/repair-db )
- SP74: Fix: SQLite table are not patched correctly for Proxy PAC service ( see http://bugs.articatech.com/show_bug.cgi?id=361 )
- SP74: Add: New procedure to upgrade php engine to 7.4.
- SP74: Add: Possibility to update Firewall extension in order to get the latest Network deep inspection service.
- SP74: Fix: Cannot connect to FTP directory using Automount.
- SP74: Fix: Cannot browse an automount directory.
- SP74: Fix: access.log in failed directory was not moved to legal logs.
- SP74: Add: Possibility to download Logs sources inside the Log Sink section ( see https://wiki.articatech.com/system/syslog/log-sink/download-sources )
- SP76: Add: New notification error for Shared memory segment on PostgreSQL ( see https://wiki.articatech.com/en/system/postgresql/could-not-open-shared-memory-segment )
- SP76: Fix: Unable to install Web-Filtering engine because the server memory is less than 2.5GB of memory free - deny possibility to install
- SP76: Fix: Sometimes priviles of the directory /var/ossec are not correctly defined for the wazhu client.
- SP76: Fix: Unable to update products using the top-right bell after SP70
- SP76: Fix: Wrong syslog clients count on the main widget for the Log sink feature.
- SP76: Fix: Browse events in Log Sink did not start search when opening the section.
- SP76: Fix: Sometimes the watchdog think that the Artica Web console monitor is not started that is not the case ( see http://bugs.articatech.com/show_bug.cgi?id=364 )
- SP76: Fix: Sometimes, building a support tool return failed to construct.
- SP76: Fix: New procedure for upgrading php7.3 to 7.4 ( 7.4 is now officially added in ISOs )
- SP78: Fix: sometimes system information is empty.
- SP78: Fix: rsyslog is turned to debug logs that fill the hard disk.
- SP78: Fix: Minor fixes.
- SP80: Fix: Port conflict with local DNS cache service and Unbound DNS service.
- SP80: Fix: Unable to save TCP/IP network interface configurations.
- SP80: Fix: Unable to remove an SMTP instance.
- SP80: Fix: Corrupted Postfix configuration in multiple-instances.
- SP82: Fix: Sometimes Web console is unable to connect to Active Directory using LDAP SSL.
- SP82: Fix: Loop inside license section in community edition
- SP82: Fix: Unable to link Artica Proxy with a remote category service.( see https://wiki.articatech.com/categories-service )
- SP84: Add: Possibility to download access logs inside the Proxy Logs Center ( see https://wiki.articatech.com/en/proxy-service/legal-logs/proxy-rules )
- SP84: Add: Log Sink TLS support.( beta mode )
- SP86: Add: Reloading proxy service after the Kerberos certificate renewal process.
- SP86: Add: Status information in Proxy ACLs in order to display if rule is in production mode or not.
- SP86: Fix: SSL wizard require a license that should not be the case.
- SP87: Fix: Unable to change the administrator email address in community edition
- SP88: Fix: Create a rule in Proxy-PAC did not restart the proxy pac service.
- SP88: Fix: Wizard rule always came back at each proxy-pac restarts.
- SP90: Fix: Web-Filter engine did not find users in Active Directory groups.
- SP90: Fix: categories uniq names are limited to 25 characters.
- SP90: Fix: Unable to change the Proxy manager email address.
- SP90: Fix: Corrupted transport table when using multiples SMTP instance in Artica SMTP edition
- SP91: Fix: Issue while removing Authorized networks in Artica SMTP edition ( see http://bugs.articatech.com/show_bug.cgi?id=370 )
- SP91: Fix: Issue on Artica-Webconsole cgi temp path permission issues that make some administration pages looping.
- SP92: Add: Possibility to reconstruct an SMTP instance ( see https://wiki.articatech.com/smtp-service/multi/reinstall )
- SP92: Add: Possibility to Change listen network interface on an SMTP instance ( see https://wiki.articatech.com/smtp-service/multi/change-interface )
- SP94: Add; Possibility to turn the Proxy SSL in emergency Mode.
- SP94: Add: New StoreID generation for more cache speed.
- SP94: Add: Revisit Proxy Caching and SSL section.
- SP94: Fix: Too many Ajax requests to the web administration console that make it slower.
- SP96: Add: Possibility to see the status of the HyperCache Dedup feature. ( see https://wiki.articatech.com/en/proxy-service/cache/hypercache )
- SP96: Fix: HyperCache Dedup create too many logs.
- SP96: Fix: Unable to save settings in proxy general section.
- SP98: Add: Rewrite the first wizard ( beta 1)
- SP100: Add: New MemCached version 1.6.19
- SP100: Fix: Top-right icon always claim about the new clamav version 1.1.0
- SP100: Fix: looping interface when browsing inside the Browsers proxy acls section.
- SP100: Add: Possibility to upload an Artica snapshot inside the first wizard Installation.
- SP100: Fix: unknown DC server on the dashboard widget when using Active Directory Kerberos method.
- SP100: Add: Possibility to see the status of ArticaTech web-filtering databases.
- SP100: Add: Possibility to reset the current settings ( see https://wiki.articatech.com/en/system/factory-reset )
- SP100: Add: Rewrite the first wizard ( beta 2)
- SP102: Add: New watchdog that makes sure the go-shield server is ready for categorization control.
- SP102: Add: New Proxy version 5.8 support
- SP102: Add: New NetData 5.38 support
- SP102: Add: New Monitor Daemon 5.33
- SP102: Add: Support of formatting Windows Events log in Log Sink feature.
- SP104: Add: Possibility to globally disable Internet checking ( https://wiki.articatech.com/en/network/check-network-connections )
- SP104: Fix: dnsdist_rules has no column named dns_caches when creating a new DNS Firewall rule.
- SP104: Fix: Progress barr stuck at 19% when updating Artica.
- SP104: Add: DNS Firewall reports categories inside realtime events.
- SP104: Add: DNS Firewall relatime events can be reported to syslog server
- SP104: Fix: Issues while detecting domains using The Shields and DNS Firewall
- SP106: Add: Possibility to display realtime requests by DNS Firewall rule ( see https://wiki.articatech.com/dns/load-balancer/realtime-by-rules )
- SP106: Add: StoreID HyperCache releases verifications
- SP106: Add: Watchdog on Proxy claim FATAL: The store_id helpers are crashing too rapidly
- SP106: Add: Possibility to unlink DNS settings from the system on the proxy service ( see https://wiki.articatech.com/proxy-service/tuning/specific-dns )
- SP106: Fix: When removing a website from a personal category, the row is not removed.
- SP106: Add: More information when adding websites in categories in AdminTrack feature.
- SP106: Add: Left Menu for HaExchange service in beta mode.
- SP106: Add: Possibility to manage unix system accounts inside OpenSSH section.
- SP106: Add: Re-design OpenSSH section.
- SP107: Fix: multiple notifications for upgrading HyperCache binary ( see http://bugs.articatech.com/show_bug.cgi?id=372 )
- SP107: Fix: Failed to start proxy service by the watchdog when systemd is installed on the Artica server.
- SP108: Fix: Artica-status crashes after Serice Pack 107
- SP110: Add: Possibility to create an SSH connection in the Auto-mount service ( see https://wiki.articatech.com/system/automount/ssh )
- SP110: Add: Possibility to backup log files stored by the Log Sink feature.( see https://wiki.articatech.com/en/system/syslog/log-sink/backup-task )
- SP110: Add: Possibility to enable a realtime monitor in the Log Sink feature ( see https://wiki.articatech.com/system/syslog/log-sink/realtime-events )
- SP112: Remove: Waiting connection on the wazhu client ( artica is unable to detect the connection status )
- SP114: Add: Notification on the top-right icon when a new Wazhu Client version is available
- SP114: Fix: Unable to renew let's Encrypt certificates on Artica for Wordpress Edition.
- SP114: Add: Minor compatibilities with Fortigate events and Artica Log Sink ( see https://wiki.articatech.com/en/system/syslog/log-sink/fortigate )
- SP114: Add: Possibility to delete a Wazuh agent from the Artica Web interface ( see https://wiki.articatech.com/system/monitoring/wazhu-client/delete-agent )
- SP114: Add: Compatibility with Artica Log Sink and Wazuh agent see ( https://wiki.articatech.com/en/system/syslog/log-sink/wazuh )
- SP114: Fix: Unable to set login=PASSTHRU in proxy service when usin a parent proxy with authentication method.
- SP114: Fix: Unable to create SSL certificates caused by table sslcertificates has no column named AsRoot
- SP114: Add: New parameter Max Unwanted replies on the DNS Cache service in order to prevent DNS poisonning attacks.
- SP114: Add: Wizard for helping SSL decryption Improvements in the Proxy service.
- SP114: Add: Possibility to download a PowerShell script for Proxy SSL certificate deployment
- SP116: Add: Proxy Parent rule name inside the Proxy realtime access monitor.
- SP116: Add: Possibility to change the listen Interface of the Web error page
- SP116: Add: DNS Firewall Support for the Web error page ( see https://wiki.articatech.com/dns/load-balancer/error-page )
- SP116: Fix: SafeSearch did not working on Qwant Search engine.
- SP116: Fix: Filtering service events are not displayed.
- SP116: Fix: Webfiltering service crashes when there is no way to find DNS
- SP116: Add: Support of the Web error page sub-certificates. ( see https://wiki.articatech.com/en/proxy-service/ssl/error-page )
- SP117: Fix: Artica Turn into Active Directory Emergency as the feature was disabled.
- SP117: Fix: Conflicts on monitoring DNS log files that cause the monitor daemon to crash.
- SP117: Add: communicate Artica Service Pack version number to License server.
- SP118: Fix: New Artica Update page did not take care of screen size.
- SP118: Fix: Unable to save error templates in reverse-proxy
- SP120: Add: Possibility to exclude some network elements from the HotSpot. ( see https://wiki.articatech.com/proxy-service/hotspot/exclude )
- SP120: Add: Possibility mount FTPs remote ressource in Auto-mount feature ( see https://wiki.articatech.com/en/system/automount/ftps )
- SP120: Add: Possibility to upgrade the Auto-mount center version.
- SP122: Fix: Unable to backup Log Sink containers using FTP.
- SP122: Fix: Unable to start Auto-mount service on old Auto-mount versions.
- SP122: Fix: Unable to connect to an FTP server with bad builded SSL certificate with Auto-mount service.
- SP122: Add: Possibility to change the behavior of Web console's drop-down lists ( see https://wiki.articatech.com/web-console/dropdown-lists )
- SP122: Fix: Issue on @ or / characters in credentials authentication for the Artica SMTP notification service.
- SP122: Add: Possibility to report uncategorized websites ( see https://wiki.articatech.com/filtering-service/report-uncategorized )
- SP122: Fix: Issue http-check only supports disable-on-404 on haCluster ( see https://wiki.articatech.com/en/proxy-service/hacluster/http-check-only-supports-disable-on-404 )
- SP122: Fix: HTTP clients use the proxy default parameters when requesting the Filtering service.
- SP122: Fix: The Filtering service crashes when trying to categorize corrupted domains.
- SP124: Fix: Auto-mount center corrupted configuration when OpenLDAP service is enabled.
- SP124: Add: Increase file descriptors for the DNS Cache service.
- SP124: Fix: Unable to install DNS Cache service because artica is unable to create the system user.
- SP124: Fix: Artica does not wait enough time before testing the proxy service port availability ( need to wait at least 3 minutes).
- SP126: Fix: Issue on License when the license token is empty
- SP126: Fix: Issue on Active Directory groups finder plugin on the proxy service.
- SP128: Fix: Artica did not displays MySQL service status in the Web console.
- SP128: Fix: /var/log/ntml.status.log was not monitored for cleaning.
- SP128: Add: Possibility to upgrade MySQL/MariaDB engine version.
- SP128: Fix: Interface Loop on the new HotSpot feature design
- SP130: Add: Possibility to change the storage directory of the Log Sink service.
- SP130: Add: Possibility to display web error page from Web-Filtering when decrypting the SSL protocol in proxy service ( see https://wiki.articatech.com/proxy-service/web-error/ssl )
- SP132: Fix: Syslog daemon issue invalid or yet-unknown config file command ImjournalRateLimitInterval
- SP132: Add: Persistent Connections support ( see https://wiki.articatech.com/proxy-service/tuning/pcon )
- SP132: Fix: Issue while creating a sub-certificate
- SP134: Add: new feature: real-time network monitoring.
- SP134: Change: Glances to HTOP web emulation.
- SP135: Fix: remove headers are not applied in reverse proxy
- SP135: Add: Possibility to redirects a domain to a domain.
- SP136: Fix: Wrong reverse-proxy status on dashboard
- SP136: Fix: Unable to compile websites after enabling pages optimization in reverse-proxy service.
- SP137: Fix: Permissions issues on winbind for NTLM proxy that turn the proxy into emergency mode.
- SP137: Add: The search engine in acls allows to search inside items too.
- SP138: Add: Double-check for the Port monitor Timeout because sometimes the issue is caused by Connection refused instead of time out.
- SP138: Fix: ACLs proxy rules status are not displayed
- SP138: Fix: small bugs
- SP139: Add: possibility to change the limit between each personal categories compilation ( see https://wiki.articatech.com/en/personal-categories/limit-compilation )
- SP140: Add: Possibility to use the HotSpot feature without need to connect the proxy to the Active Directory service.
- SP140: Change: Zabbix client interface.
- SP140: Change: Clock settings interface.
- SP140: Fix: the HotSpot is unable to bind the defined network interface.
- SP140: Add: Notification for new Zabbix Agent version.
- SP140: Add: Possibility to define the log level of the Zabbix Agent
- SP140: Add: Format correct dates and times in the Zabbix Agent logs browser.
- SP140: Add: Monitoring zabbix_agentd.log log file size.
- SP142: Add: Better helps when connecting Artica to an Active Directory server using NTLM
- SP142: Change: Active Directory Web API Service interface
- SP142: Update: HaProxy 2.7.7 version to repository
- SP142: Fix: Cannot change the "Error, wrong credentials" text inside the HotSpot skin.
- SP142: Fix: Issue on HotSpot skins for ISO-8859-1 characters.
- SP142: Update: DNS Firewall 1.8.0 version to repository
- SP144: Fix: Unable to install DNS cache service after uninstalled it.
- SP146: Fix: Ensure that failover database is built during installation.
- SP146: Add: new proxy antivirus Scanner engine directly connected to the proxy using eCAP protocol.
- SP146: Fix: Artica did not clean the reverse-proxy service log.
- SP146: Fix: Artica did not renew Let's Encrypt certificate for Wordpress edition.
- SP148: Fix: Proxy PAC will not build all PAC rules.
- SP150: Fix: Proxy Crashes after SP148
- SP151: Fix: Minors bug fixes
- SP152: Fix: Minors bug fixes
- SP154: Add: New Feature Artica AD Agent ( see https://wiki.articatech.com/proxy-service/authentication/ad-agent )
- SP154: Add: New Feature eCAP Antivirus connector ( see https://wiki.articatech.com/en/proxy-service/icap-av/ecap-av )
- SP154: Fix: Some security holes discovered by the Siemens Energy SOC team
- SP156: Fix: Unable to change time under the web console.
- SP156: Fix: eCAP proxy is unable to get its configuration. see (http://bugs.articatech.com/show_bug.cgi?id=385 )
- SP156: Fix: Unable to save Analyze IP addresses reputation in The Shields Settings.
- SP158: Add: eCAP proxy antivirus now supports syslog and remote syslog configuration.
- SP158: Fix: Issue with mixed Proxy + Active Directory + HotSpot.
- SP158: Fix: DNS global configuration was not correctly reconfigured when installing/uninstalling the Local DNS Cache service.
- SP158: Change: Re-arrange the Active Directory menu.
- SP160: Update Redis server 7.0.11
- SP160: Fix: Unable to start ntopng service ( error 500 in Artica Web console )
- SP162: Change: End-of-life of the 4.40 version, add procedure to upgrade to 4.50 LTS.